Kiddio Checks · Equipment

What size equipment passes Manual S?

Find the capacity range Manual S allows for your Manual J loads, or check a unit you have already picked. Georgia's residential code requires Manual S sizing.

No equipment picked yet? Enter your Manual J cooling loads. The check returns the capacity range Manual S allows, so you shop for the right size from the start.

Enter your Manual J loads and the unit's capacity at design conditions from the manufacturer's expanded performance data.

Btu/h
Btu/h
Equipment at design conditions (expanded performance data)
Btu/h
Btu/h
Btu/h

Latent values are calculated: total minus sensible. Nothing is saved unless you download the report.

This check screens your numbers against the Manual S size limits. It does not replace a Manual S selection using the manufacturer's expanded performance data. Rules current as of November 19, 2026.
How it works

Find My Size applies the Manual S limits to your loads and returns the capacity window. Check My Unit divides each capacity by its matching load and plots it against that window. Houses with a sensible heat ratio of 0.95 or higher use the stricter dry sizing condition.

Sources
  • ANSI/ACCA 3 Manual S – 2023 with Addenda A and B (2024), Tables N2.3.1, N2.3.2, and N2.3.4
  • 2024 International Residential Code, Section M1401.3, with 2026 Georgia amendments
Common questions
  • Why not nameplate tonnage? Capacity changes with outdoor temperature and airflow. Manual S uses the capacity at your design conditions.
  • Unit fails latent? Try lower indoor airflow, a two-speed unit, or a different coil match.